ITK Implementation
Application Roles | Responsible for sending | Responsible for receiving |
---|---|---|
NHS 111 Call Handler System (POCD_AR000004GB01) |
| |
NHS 111 General Practitioner Receiving System (POCD_AR000005GB01) | ||
NHS 111 Emergency Department Receiving System (POCD_AR000006GB01) | ||
NHS 111 Out of Hours Receiving System (POCD_AR000007GB01) | ||
NHS 111 Repeat Caller Query Placer System (QUPA_AR000008GB01) | ||
NHS 111 Repeat Caller Query Fulfiller System (PRPA_AR000008GB01) | ||
NHS 111 Report Copy Recipient (POCD_AR000009GB01) | ||
NHS 111 Ambulance Request Receiving System (REPC_AR000001GB01) | ||
NHS 111 Repeat Caller Repository Receiving System (REPC_AR000008GB01) |
Trigger Events
Interactions
NHS111 Report Interactions
Primary General Practitioner Recipient NHS 111 CDA Document (urn:nhs-itk:interaction:primaryGeneralPractitionerRecipientNHS111CDADocument-v2-0)
Communicates NHS 111 Report to a General Practitioner recipient where the recipient is recommended to act upon information carried in the document. Note: This interaction has a message format that is constrained using HSCIC templates. This format is validated using a two level process. There are two sets of schema one for each level. The sender of this interaction must build all instances to the "on the wire" format using the generic CDA definition indicated in the wire format below. These instances must also conform to the rules stated in the conformance definition indicated in the conformance format below. The second level of validation requires transformation before schema validation can take place. For full details of this validation process please see the "Technical Guidance for Templated CDA Domains" section under the associated specifications tab. Sender: NHS 111 Call Handler System (POCD_AR000004GB01) Receiver: NHS 111 General Practitioner Receiving System (POCD_AR000005GB01) Message:
Transmission Wrapper: ITK Distribution Envelope (Version 2.0) (distributionEnvelope-v2-0) Web Service Wrapper: Send NHS 111 Report (Version 2.0) (Input) (SendNHS111Report-v2-0 (NHS111-v3-0.wsdl)) |
Primary Emergency Department Recipient NHS 111 CDA Document: (urn:nhs-itk:interaction:primaryEmergencyDepartmentRecipientNHS111CDADocument-v2-0)
Communicates an NHS 111 Report to a Emergency Department recipient where the recipient is recommended to act upon information carried in the document. Note: This interaction has a message format that is constrained using HSCIC templates. This format is validated using a two level process. There are two sets of schema one for each level. The sender of this interaction must build all instances to the "on the wire" format using the generic CDA definition indicated in the wire format below. These instances must also conform to the rules stated in the conformance definition indicated in the conformance format below. The second level of validation requires transformation before schema validation can take place. For full details of this validation process please see the "Technical Guidance for Templated CDA Domains" section under the associated specifications tab. Sender: NHS 111 Call Handler System (POCD_AR000004GB01) Receiver: NHS 111 Emergency Department Receiving System (POCD_AR000006GB01) Message:
Transmission Wrapper: ITK Distribution Envelope (Version 2.0) (distributionEnvelope-v2-0) Web Service Wrapper: Send NHS 111 Report (Version 2.0) (Input) (SendNHS111Report-v2-0 (NHS111-v3-0.wsdl)) |
Primary Out of Hour Recipient NHS 111 CDA Document (urn:nhs-itk:interaction:primaryOutofHourRecipientNHS111CDADocument-v2-0)
Communicates NHS 111 Report to a Out of Hour recipient where the recipient is recommended to act upon information carried in the document. Note: This interaction has a message format that is constrained using HSCIC templates. This format is validated using a two level process. There are two sets of schema one for each level. The sender of this interaction must build all instances to the "on the wire" format using the generic CDA definition indicated in the wire format below. These instances must also conform to the rules stated in the conformance definition indicated in the conformance format below. The second level of validation requires transformation before schema validation can take place. For full details of this validation process please see the "Technical Guidance for Templated CDA Domains" section under the associated specifications tab. Sender: NHS 111 Call Handler System (POCD_AR000004GB01) Receiver: NHS 111 Out of Hours Receiving System (POCD_AR000007GB01) Message:
Transmission Wrapper: ITK Distribution Envelope (Version 2.0) (distributionEnvelope-v2-0) Web Service Wrapper: Send NHS 111 Report (Version 2.0) (Input) (SendNHS111Report-v2-0 (NHS111-v3-0.wsdl)) |
Primary Repeat Caller Repository Recipient NHS 111 CDA Document (urn:nhs-itk:interaction:primaryRepeatCallerRepositoryRecipientNHS111CDADocument-v2-0)
Communicates NHS 111 Report to a Repeat Caller Repository recipient where the recipient is recommended to act upon information carried in the document. Note: This interaction has a message format that is constrained using HSCIC templates. This format is validated using a two level process. There are two sets of schema one for each level. The sender of this interaction must build all instances to the "on the wire" format using the generic CDA definition indicated in the wire format below. These instances must also conform to the rules stated in the conformance definition indicated in the conformance format below. The second level of validation requires transformation before schema validation can take place. For full details of this validation process please see the "Technical Guidance for Templated CDA Domains" section under the associated specifications tab. Sender: NHS 111 Call Handler System (POCD_AR000004GB01) Receiver: NHS 111 Repeat Caller Repository Receiving System (REPC_AR000008GB01) Message:
Transmission Wrapper: ITK Distribution Envelope (Version 2.0) (distributionEnvelope-v2-0) Web Service Wrapper: Send NHS 111 Report (Version 2.0) (Input) (SendNHS111Report-v2-0 (NHS111-v3-0.wsdl)) |
Copy Recipient NHS 111 CDA Document (urn:nhs-itk:interaction:copyRecipientNHS111CDADocument-v2-0)
Communicates NHS 111 Report to a copy recipient where the document is for information only and NO system action is defined. Note: This interaction has a message format that is constrained using HSCIC templates. This format is validated using a two level process. There are two sets of schema one for each level. The sender of this interaction must build all instances to the "on the wire" format using the generic CDA definition indicated in the wire format below. These instances must also conform to the rules stated in the conformance definition indicated in the conformance format below. The second level of validation requires transformation before schema validation can take place. For full details of this validation process please see the "Technical Guidance for Templated CDA Domains" section under the associated specifications tab. Sender: NHS 111 Call Handler System (POCD_AR000004GB01) Receiver: NHS 111 Report Copy Recipient (POCD_AR000009GB01) Message:
Transmission Wrapper: ITK Distribution Envelope (Version 2.0) (distributionEnvelope-v2-0) Web Service Wrapper: Send NHS 111 Report (Version 2.0) (Input) (SendNHS111Report-v2-0 (NHS111-v3-0.wsdl)) |
Nullify NHS 111 CDA Document (urn:nhs-itk:interaction:nullifyNHS111CDADocument-v1-0)
Communicates the nullification (by replacement) of any NHS 111 Report sent to any recipient.Must be sent to all information recipients (including copy recipients). Note: This interaction has a message format that is constrained using HSCIC templates. This format is validated using a two level process. There are two sets of schema one for each level. The sender of this interaction must build all instances to the "on the wire" format using the generic CDA definition indicated in the wire format below. These instances must also conform to the rules stated in the conformance definition indicated in the conformance format below. The second level of validation requires transformation before schema validation can take place. For full details of this validation process please see the "Technical Guidance for Templated CDA Domains" section under the associated specifications tab. Sender: NHS 111 Call Handler System (POCD_AR000004GB01) Receiver: NHS 111 General Practitioner Receiving System (POCD_AR000005GB01) Receiver: NHS 111 Emergency Department Receiving System (POCD_AR000006GB01) Receiver: NHS 111 Out of Hours Receiving System (POCD_AR000007GB01) Receiver: NHS 111 Repeat Caller Repository Receiving System (REPC_AR000008GB01) Receiver: NHS 111 Report Copy Recipient (POCD_AR000009GB01) Message:
Transmission Wrapper: ITK Distribution Envelope (Version 2.0) (distributionEnvelope-v2-0) Web Service Wrapper: Send NHS 111 Report (Version 2.0) (Input) (SendNHS111Report-v2-0 (NHS111-v3-0.wsdl)) |