Laboratory results
Resource purpose
Laboratory Observation resources represent NHS Health Check laboratory results. They can represent a result directly or group related results, such as a serum lipids panel.
Resource structure
This example shows a panel using hasMember to reference its result Observations. Direct results use a value; if a result is unavailable, dataAbsentReason can explain why.
{
"resourceType": "Observation",
"id": "311a3662-4b3f-4a8f-8a87-97e5fba67a07",
"meta": {
"versionId": "1",
"lastUpdated": "2026-10-20T05:22:04.934706Z"
},
"status": "final",
"category": [
{
"coding": [
{
"system": "http://terminology.hl7.org/CodeSystem/observation-category",
"code": "laboratory",
"display": "Laboratory"
}
],
"text": "Laboratory - Total Cholesterol, HDL, and Cholesterol to HDL ratio"
}
],
"code": {
"coding": [
{
"system": "http://snomed.info/sct",
"code": "365793008",
"display": "Finding of cholesterol level (finding)"
}
]
},
"subject": {
"identifier": {
"system": "https://fhir.nhs.uk/Id/nhs-number",
"value": "9033886480"
}
},
"encounter": {
"reference": "Encounter/ab2acd48-6411-4004-b636-d6cbf6fb5deb",
"type": "Encounter"
},
"effectiveDateTime": "2026-10-20T05:22:01Z",
"hasMember": [
{
"reference": "Observation/ca35ab8c-b0e5-4f2b-81fd-1d873ad312b8"
},
{
"reference": "Observation/b048a351-e16a-4784-b656-a569a371d072"
},
{
"reference": "Observation/5b19eb39-22b2-40b2-8328-32ef3003da9a"
}
]
}
Element specification
| Element | Cardinality | Type | Requirement |
|---|---|---|---|
id |
0..1 | id |
Resource identifier |
status |
1..1 | code |
Must be final |
category |
1..* | CodeableConcept |
Must include the laboratory category |
code |
1..1 | CodeableConcept |
Laboratory code from the options below |
subject |
1..1 | Reference |
Patient who is the subject of the observation |
encounter |
1..1 | Reference |
Related Encounter |
effective[x] |
1..1 | dateTime or Period |
When the observation was effective |
performer |
1..* | Reference |
Organization or Practitioner responsible for the observation |
valueQuantity |
0..1 | Quantity |
Direct quantitative result, when applicable |
hasMember |
0..* | Reference |
Related result Observations, when this Observation groups results |
dataAbsentReason |
0..1 | CodeableConcept |
Reason a result value is absent |
At least one of value[x], dataAbsentReason, component or hasMember must be present.
Laboratory code options
Use one of these SNOMED CT codes for code:
| Use | Code | Display |
|---|---|---|
| Serum lipids panel | 1005661000000103 |
Serum lipids level (observable entity) |
| Total cholesterol | 1005671000000105 |
Serum cholesterol level (observable entity) |
| HDL cholesterol | 1005681000000107 |
Serum high density lipoprotein cholesterol level (observable entity) |
| Total cholesterol:HDL ratio | 1028551000000102 |
Total cholesterol:high density lipoprotein ratio (observable entity) |
| HbA1c | 1003671000000109 |
Haemoglobin A1c level (observable entity) |
The rules above do not set units or reference ranges for valueQuantity. Supply a quantity appropriate to the coded result. A failed test can omit the result value and provide dataAbsentReason instead.
Edit this page on GitHub